NFPA 802013 EDITIONDECODED

Fire Doors & Opening Protectives

Practical interpretations, field tips, and real-world stories — not a copy of the standard.

20
CHAPTERS
197
TOPICS
⚠
This guide provides practical interpretations written in our own words. It is not a substitute for the official standard. Purchase NFPA 80 at nfpa.org | Fire Doors article | 13-Point Checklist | Fire Door Dojo
Ch. 1

Administration

What NFPA 80 covers, why it exists, and how it treats existing buildings

4 topics▼
Ch. 2

Referenced Publications

The other standards NFPA 80 leans on

4 topics▼
Ch. 3

Definitions

The words a fire door inspector needs to get right

14 topics▼
Ch. 4

General Requirements

Labels, job-site preps, signs, glass, hardware, detectors and the wall around the door

18 topics▼
Ch. 5

Care and Maintenance

How fire doors are tested, inspected and kept working

39 topics▼
Ch. 6

Swinging Doors with Builders Hardware

Ordinary hinged fire doors: frames, clearances, hinges, closers, latches and the rest of the hardware

43 topics▼
Ch. 7

Swinging Doors with Fire Door Hardware

Tin-clad and sheet metal swinging doors on heavy fire door hardware

9 topics▼
Ch. 8

Horizontally Sliding Doors

Sliding fire doors that roll sideways along a track

6 topics▼
Ch. 9

Special-Purpose Horizontally Sliding Accordion or Folding Doors

Folding and accordion fire doors that stack to one side

4 topics▼
Ch. 10

Vertically Sliding Fire Doors

Fire doors that drop down vertically over an opening

5 topics▼
Ch. 11

Rolling Steel Doors

Coiling steel fire doors and how they drop and close

9 topics▼
Ch. 12

Fire Shutters

Shutters that protect window-type openings

3 topics▼
Ch. 13

Service Counter Fire Doors

Small fire doors over service counters and pass-through windows

4 topics▼
Ch. 14

Hoistway Doors for Elevators and Dumbwaiters

Elevator and dumbwaiter landing doors as fire doors

4 topics▼
Ch. 15

Chute Doors

Doors on trash and linen chutes

1 topics▼
Ch. 16

Access Doors

Small rated access panels in walls, floors and ceilings

3 topics▼
Ch. 17

Fire Windows

Rated windows: frames, glazing size and labels

5 topics▼
Ch. 18

Glass Block Assemblies

Fire-rated glass block walls in openings

2 topics▼
Ch. 19

Installation, Testing, and Maintenance of Fire Dampers

Fire dampers: installing, testing and keeping them working

11 topics▼
Ch. 20

Fabric Fire Safety Curtains

Stage fire curtains across proscenium openings

9 topics▼