NFPA 70E Study Tool

Certified Electrical Safety Compliance Professional (CESCP) — NFPA 70E, 2024 Edition

NFPA 70EEXAM PREP

NFPA 70E / CESCP Review

Built on the published CESCP exam blueprint — NFPA 70E, Standard for Electrical Safety in the Workplace, 2024 Edition. Covers the electrical safety program and the hierarchy of risk control, establishing an electrically safe work condition, energized work permits, arc flash and shock risk assessment, PPE selection, and special equipment from batteries to capacitors.

150
Questions in bank
4
Domains
3 hr
Full exam
70%
Benchmark
CODE EDITION USED THROUGHOUT THIS TOOL

Written against NFPA 70E (2024 Edition) — the CESCP body of knowledge. The 2027 edition is now current.. The CESCP is open book, but only on the printed NFPA 70E — and its body of knowledge is the 2024 edition while the 2027 edition became the current standard in May 2026. The book on your shelf at work may not be the book you sit the exam with, so check the spine before you walk in.

Study Domains (4 Areas)

I. Electrical Safety Programs
30%
II. Establishing an Electrically Safe Work Condition
29%
III. Work Involving Electrical Hazards
31%
IV. Safety Requirements for Special Equipment
10%
✦ What this exam pays
Professional-tier exam
Any attempt — pass or fail+5 SRP
Practice run at 80%++18 SRP
Full simulation at 80%++45 SRP
Perfect 100% — on top of the pass+24 SRP

Your first try on this exam adds a flat +25. Harder credentials pay more — the full ladder runs Foundation → Technician → Professional → Flagship.

ABOUT THIS EXAM · NFPA

NFPA CESCP — Certified Electrical Safety Compliance Professional

NFPA 70E is a STANDARD, not a certification. The credential built on it is NFPA's CESCP — 110 questions, 3 hours, open book on the printed 70E. The catch worth knowing before you register: the CESCP body of knowledge is the 2024 edition, while the 2027 edition became the current standard in May 2026. The book you work from may not be the book you test on.

Issuer
NFPA
Cost
Varies by path
See note below
Renewal cycle
3 years
Format
Proctored computer-based exam at testing centers worldwide. 110 multiple-choice questions (100 scored + 10 unscored pretest items)
How to register
Proctored computer-based exam at testing centers worldwide. 110 multiple-choice questions (100 scored + 10 unscored pretest items), 3-hour limit. OPEN BOOK — the printed NFPA 70E, 2024 edition is the only reference permitted in the testing room. English only.. Register at NFPA →
Cost note
NFPA does not publish CESCP fees in the program overview — the application fee (which includes the initial exam), retest fee and three-year recertification fee are listed on the NFPA CESCP page. Verify before applying.
Eligibility
All candidates: high school diploma or equivalent, plus 40 hours of NFPA 70E or other electrical safety training within the last three years (teaching approved classes counts for up to 20 of those hours). Then, by role — Electricians: licensed with 8,000 hours on electrical power systems, or proof of the job role with 8,000 hours. Electrical engineers: associate degree + 8,000 hours, bachelor's or higher + 4,000 hours, or a licensed PE. Everyone else: CSP + 6,000 hours, a bachelor's in engineering/technology + 6,000 hours, or a facilities/plant safety role with 20,000 hours.
Renewal
Recertification every three years through a points-based system. Once your application is approved you have 12 months to sit and pass the exam.. See the full renewal guide →