Stairwell Pressurization Testing
A study course for the ICB Fire and Smoke Damper Technician Stairwell Endorsement: how stair pressurization works, reading pressure and door force, running a periodic test inside your limits, the code numbers, and who can get certified
← All courses
Open →

ICB · Stairwell Endorsement
5 modules13 lessonsAbout 1 hour27 quick-check questionsRead along
What you get, and what your employer still does
- Contact hours
- Up to 1 hour — the time you are actually active, rounded down to the half hour
- Final assessment
- 20 questions, 73% to pass, retakes allowed
- Employer’s part
- This course does not train you on your own buildings or instruments. Test at least one stair alongside an experienced technician or supervisor, with building staff running the system, before you test on your own.
- Repeat it
- Before each round of periodic stair tests, and when your jurisdiction adopts a new edition of the IBC, IFC or NFPA 92.
A study aid, not an accredited course. This is here to help you prepare. It is not an accredited or certified course. It does not replace a school, an official or accredited class, or training that a certifying body, employer or agency requires, and it does not earn a credential, license or card.
When you finish, you'll be able to
- Explain how a pressure difference across a stair door keeps smoke out, and what breaks it
- Tell single from multiple injection, compensated from noncompensated, dedicated from nondedicated systems
- Read static, velocity and total pressure, and account for stack effect, wind and temperature
- Use a manometer, tubing and a door force gauge correctly, and record ambient conditions
- Run a periodic pressure and door-force test inside a technician’s limits and judge it against the criteria
- Find the numbers in NFPA 92, the IBC, the IFC and NFPA 101, and know who may test and how to get certified
How this course works · 1-minute read
Lessons are slides
Use Back / Next or the ← → arrow keys. The gold bar above each slide jumps to any slide, and marks the Quick Checks before you reach them.
Quick Checks
27 short questions sit inside the lessons. Pick an answer and the right one and the explanation appear straight away. They are practice — nothing is recorded.
Every answer has a source
Gold citation cards name the section and how to find it in your book. “Read the full text” opens our plain-language decode of that section.
Your place is saved
Sign in and the course remembers the slide you stopped on. A lesson is marked done when you press Mark lesson complete on its last slide — you can unmark it to study it again.
Then the final and your employer
A 20-question final assessment (73% to pass) unlocks the certificate with your contact hours. Then print the practical checkoff: your employer’s competent person covers your site and checks you hands-on.
Final assessment
20 questions · 73% to pass · opens when every lesson is done
Continuing education
Finish every lesson and pass the final assessment and you can print a completion certificate with the date, the course version and your measured contact hours — the time you were active in the course, rounded down to the half hour. Contact hours on a certificate of completion. Certifying bodies decide what counts toward renewal; LifeSafetyWiki is not an IACET-accredited provider.